The operating principles of this gauge are similar to the Penning gauge except that the electrons are produced by a hot filament and accelerated to a grid. The pressure range covered is either 1 to 10-5 torr or 10-2 to 10-7 torr, depending on the electrode structure. Electrons emitted from the filament ionize residual gas molecules in the container being evacuated; the ion current